CONTACT RATINGS
Application
Contact Arrangement | 1H, 1D, 1Z |
Contact Resistance | ≤ 100mΩ |
Contact Material | Silver Alloy |
Contact Rating(Resistive) | 80A 28VDC; 80A 240VAC |
Max. Switching Voltage | 240VAC/28VDC |
Max. Switching Current | 80A |
Max. Switching Power | 19200VA/2240W |
Mechanical Life | 1×10 6 operations |
Electrical Life | 5×104 operations |
COIL DATA
Nominal VDC | Pick-up Voltage (Max.) VDC | Drop-out Voltage (Min.) VDC | *Max. Allowable VDC | Coil Resistance Ω± 10% |
12 | 9.00 | 1.2 | 13.2 | 40 |
24 | 18.0 | 2.4 | 26.4 | 160 |
1 10 | 82.5 | 1 1 | 121 | 3364 |
220 | 165.0 | 22 | 242 | 13414 |
Nominal VAC | Pick-up Voltage (Max.) VAC | Drop-out Voltage (Min.) VAC | *Max. Allowable VAC | Coil Resistance Ω± 10% |
12 | 9.60 | 3.6 | 13.2 | 4.8 |
24 | 19.2 | 7.2 | 26.4 | 19.2 |
1 10 | 88.0 | 33 | 121 | 403.3 |
220 | 176.0 | 66 | 242 | 1614 |
CHARACTERISTICS
Insulation Resistance | 200MΩ (at 500VDC) | |
Dielectric Strength | Between coil & contacts | 2500VAC 1min |
Between open contacts | 1min | |
Operate time (at nomi. volt.) | ≤25ms | |
Release time (at nomi. volt.) | ≤ 15ms | |
Humidity | 35% ~ 85% RH | |
Storage Condition | -25°C~+65°C | |
Operating Condition | -25°C~+55°C | |
UL Class F | Insulation System Class F | |
Shock Resistance | Functional | 98m/s2 |
Destructive | 980m/s2 | |
Vibration resistance | 10Hz to 55Hz 1.5mm DA | |
Unit weight | Approx. 240g | |
Construction | Dust Cover Type |
ORDERING INFORMATION
COIL
Coil Power | DC:3.6W AC:7.5VA |
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Outline Dimensions | Wiring Diagram (Bottom view) |
Features
·Firm structure, strong shock and vibration resistance, long service life. . Load switching current: 80A .1 sets of contact installation are available. . Available in socket type and flange type.